Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Short to Voltage of Signal Circuit
|
- Ignition ON
- Air conditioning system OFF
- Blower stage 0 selected
- Is the following component switched off?
M1_A13 Motor - Blower, Passenger Compartment
|
Test okay?
|
|
T002
|
Check: Interruption of Voltage Supply Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
Y1_A13 Blower Regulator
- Ignition ON
- Connect test lamp ( 21 W ) and multimeter in parallel and measure voltage between the following terminals:
Y1_A13 Blower Regulator Wiring harness connector (wiring harness side) terminal 1 & Ground
|
greater than 11 V
|
|
|
T003
|
Check: Circuit Interruption of Ground Circuit
|
- Connect test lamp ( 21 W ) and multimeter in parallel and measure voltage between the following terminals:
Y1_A13 Blower Regulator Wiring harness connector (wiring harness side) terminal 1 & Y1_A13 Blower Regulator Wiring harness connector (wiring harness side) terminal 3
|
greater than 11 V
|
|
|
T004
|
Check: Interruption of Signal Circuit
|
- Blower stage
(Automatic Climate Control SAC) 4
(Electronic Climate Control ECC) 7
selected
- Measure voltage between the following terminals:
Y1_A13 Blower Regulator Wiring harness connector (wiring harness side) terminal 2 & Ground
|
(Automatic Climate Control SAC)
4.8 ... 5.2 V
(Electronic Climate Control ECC)
4.8 ... 5.2 V
|
|
|
T005
|
Check: Component
|
- Ignition OFF
- Disconnect wiring harness connector from:
Y1_A13 Blower Regulator Wiring harness connector colour RD and Y1_A13 Blower Regulator Wiring harness connector colour BK
- Ignition ON
- Connect fused jumper wire to:
Y1_A13 Blower Regulator Wiring harness connector (wiring harness side) wiring colour RD & Battery voltage
- Connect unfused jumper wire to:
Y1_A13 Blower Regulator Wiring harness connector (wiring harness side) wiring colour BK & Ground
Note:
Wiring colours: BK=Black, BN=Brown, BU=Blue, GD=Gold, GN=Green, GY=Grey, OG=Orange, PK=Pink, RD=Red, SR=Silver, TQ=Turquoise, VT=Violet, WH=White, YE=Yellow, L=Light, D=Dark
|
Is the following component switched on?
M1_A13 Motor - Blower, Passenger Compartment
|
|
T006
|
Check: Short to Voltage of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A1_A14 Control Unit - Climate Control (Wiring Harness Connector XC42 )
- Ignition ON
- Measure voltage between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 3 (XC42) & Ground
|
less than 0.3 V
|
|
|
T007
|
Check: Short to Ground of Signal Circuit
|
- Ignition OFF
Measure resistance between the following terminals: A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 3 (XC42) & Ground
|
greater than 500 kOhm
|
|
|
T008
|
Check: Interruption of Voltage Supply Circuit
|
- Measure resistance between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 3 (XC42) & Y1_A13 Blower Regulator Wiring harness connector (wiring harness side) terminal 4
|
less than 5 Ohm
|
|
|
T009
|
Check: Interruption of Signal Circuit
|
- Blower stage
(Automatic Climate Control SAC) 4
(Electronic Climate Control ECC) 7
selected
- Measure voltage between the following terminals:
Y1_A13 Blower Regulator Wiring harness connector (wiring harness side) terminal 2 & Ground
|
(Automatic Climate Control SAC)
less than 4.8 V
(Electronic Climate Control ECC)
less than 4.8 V
|
|
|
T010
|
Check: Short to Voltage of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
Y1_A13 Blower Regulator
- Ignition ON
- Blower stage 0 selected
- Measure voltage between the following terminals:
Y1_A13 Blower Regulator Wiring harness connector (wiring harness side) terminal 2 & Ground
|