Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Short to Voltage of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A1_A14 Control Unit - Climate Control (Wiring Harness Connector XC43 )
- Ignition ON
- Measure voltage between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 7 (XC43) & Ground
|
less than 0.3 V
|
|
|
T002
|
Check: Short to Ground/Interruption of Signal Circuit
|
- Ignition OFF
- Connect fused jumper wire to:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 7 (XC43) & Battery voltage
- Measure voltage between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 3 (XC43) & Ground
|
greater than 11 V
|
|
|
T003
|
Check: Short to Ground/Interruption of Signal Circuit
|
- Measure voltage between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 4 (XC43) & Ground
|
greater than 11 V
|
|
|
T004
|
Check: Short to Ground/Interruption of Signal Circuit
|
- Measure voltage between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 19 (XC43) & Ground
|
greater than 11 V
|
|
|
T005
|
Check: Short to Ground/Interruption of Signal Circuit
|
- Measure voltage between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 20 (XC43) & Ground
|
greater than 11 V
|
|
|
T006
|
Check: Short to Ground of Signal Circuit
|
- Check the following component for proper operation:
Fuse of the fused jumper wire
|
Test okay?
|
|
T007
|
Check: Interruption of Signal Circuit
|
- Disconnect wiring harness connector from:
M1_A14 Stepper Motor - Air Distribution Flap
- Measure voltage between the following terminals:
M1_A14 Stepper Motor - Air Distribution Flap Wiring harness connector (wiring harness side) terminal 2 & Ground
|
greater than 11 V
|
|
|
T008
|
Check: Short to Voltage of Signal Circuit
|
- Disconnect wiring harness connector from:
M1_A14 Stepper Motor - Air Distribution Flap
- Measure voltage between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 7 (XC43) & Ground
|
less than 0.3 V
|
|
|
T009
|
Check: Short to Voltage of Signal Circuit
|
- Disconnect wiring harness connector from:
M2_A14 Stepper Motor - Mixed Air Flap
- Measure voltage between the following terminals:
A1_A14 Control Unit - Climate Control Wiring harness connector (wiring harness side) terminal 7 (XC43) & Ground
|
less than 0.3 V
|
|
|