Ribbed V-Belt Guide Roller, Replace
Remove
2. |
Remove air cleaner housing (5) with air intake hose
• |
Detach wiring harness plug (2) from hot film mass air flow
meter
|
• |
Detach air intake hose from air intake pipe
|
• |
Detach air cleaner housing from wheel housing
|
• |
Detach water drain hose (3) from air cleaner housing
|
|
|
|
3. |
Remove ribbed V-belt
• |
Mark direction of rotation
|
• |
Apply tension to ribbed V-belt tensioner via bolt (1) in the
direction of the arrow
|
• |
Fix ribbed V-belt tensioner to bore (2)
|
|
|
|
4. |
Remove ribbed V-belt guide roller (2)
|
|
|
Install
5. |
Install ribbed V-belt guide roller
|
6. |
Insert ribbed V-belt
Note: Note running
direction of ribbed V-belt
• |
Position ribbed V-belt
– |
I. Ribbed V-belt without air conditioning
|
– |
II. Ribbed V-belt with air conditioning
|
|
• |
Apply tension to ribbed V-belt tensioner via bolt (1) in the
direction of the arrow
|
• |
Release ribbed V-belt tensioner
|
|
|
|
7. |
Install air cleaner housing with air intake hose
• |
Attach water drain hose to air cleaner housing
|
• |
Attach air intake hose to air intake pipe
|
• |
Connect wiring harness plug to air mass flow meter
|
|
|