vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

C-030 Exhaust Gas Temperature Sensor 1 Circuit > < C-028 O2 Sensor Circuit

C-029 - O2 Sensor Heater Circuit

Test

Work Order Description

Nominal Value

T001

Check: Interruption of Voltage Supply Circuit

  • Ignition OFF
  • Disconnect wiring harness connector from:
    B56 Sensor - Oxygen, Exhaust, Heated
  • Remove electrical component from socket:
    K2_X125 Relay - Engine Control Unit
  • Connect fused jumper wire to:
    K2_X125 Relay - Engine Control Unit
    Socket Terminal 87
    &
    Battery voltage
  • Measure voltage between:
    B56 Sensor - Oxygen, Exhaust, Heated
    Wiring harness connector (wiring harness side) terminal 4
    &
    Ground

greater than 11 V

Voltage Measurement Current Value: V
Yes: No:
T002

Check: Short to Voltage of Ground Circuit

  • Remove fused jumper wire
  • Disconnect wiring harness connector from:
    A84 Control Unit - Engine
    (Wiring Harness Connector XC53 )
  • Ignition ON
  • Measure voltage between:
    B56 Sensor - Oxygen, Exhaust, Heated
    Wiring harness connector (wiring harness side) terminal 3
    &
    Ground

less than 0.3 V

Voltage Measurement Current Value: V
Yes: No:
T003

Check: Short to Ground of Signal Circuit

  • Ignition OFF
  • Measure resistance between:
    B56 Sensor - Oxygen, Exhaust, Heated
    Wiring harness connector (wiring harness side) terminal 3
    &
    Ground

greater than 500 kOhm

Resistance Measurement Current Value: kOhm
Yes: No:
T004

Check: Circuit Interruption of Ground Circuit

  • Measure resistance between the following terminals:
    B56 Sensor - Oxygen, Exhaust, Heated
    Wiring harness connector (wiring harness side) terminal 3
    &
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 51 (XC53)

less than 5 Ohm

Resistance Measurement Current Value: Ohm
Yes: No:
T005

Check: Component

  • Measure resistance between the following terminals:
    B56 Sensor - Oxygen, Exhaust, Heated
    Wiring harness connector (component side) terminal 4
    &
    B56 Sensor - Oxygen, Exhaust, Heated
    Wiring harness connector (component side) terminal 3

1 ... 20 Ohm

Resistance Measurement Current Value: Ohm
Yes: No:


Result

Cause Of Fault

E001 Result: Defective Component
  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E002 Result: Defective Component
  • Defective component:
    B56 Sensor - Oxygen, Exhaust, Heated

Important:

After replacing the following component the programming function for the replacement of the corresponding component has to be performed by using the diagnostic tester:

B56 Sensor - Oxygen, Exhaust, Heated

E003 Result: Interruption
  • Circuit interruption between:
    B56 Sensor - Oxygen, Exhaust, Heated
    Wiring harness connector (wiring harness side) terminal 3
    &
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 51 (XC53)
E004 Result: Short to Ground
  • Short circuit to ground between:
    B56 Sensor - Oxygen, Exhaust, Heated
    Wiring harness connector (wiring harness side) terminal 3
    &
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 51 (XC53)
E005 Result: Short to Voltage
  • Short circuit to voltage between:
    B56 Sensor - Oxygen, Exhaust, Heated
    Wiring harness connector (wiring harness side) terminal 3
    &
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 51 (XC53)
E006 Result: Interruption
  • Circuit interruption between:
    X125 Underhood Electronic Module
    Wiring harness connector (wiring harness side) terminal 28 (XE3)
    &
    B56 Sensor - Oxygen, Exhaust, Heated
    Wiring harness connector (wiring harness side) terminal 4

or

  • Defective component:
    X125 Underhood Electronic Module

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.






C-030 Exhaust Gas Temperature Sensor 1 Circuit > < C-028 O2 Sensor Circuit