Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Diagnostic Trouble Code stored
|
Is the following Diagnostic Trouble Code stored?
P1400
Exhaust Gas Recirculation Valve Stuck
|
|
|
|
T002
|
Check: Interruption of Voltage Supply Circuit
|
- Disconnect wiring harness connector from:
Y56 Solenoid Valve - Exhaust Gas Recirculation
- Ignition ON
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 2 & Ground
|
4.8 ... 5.2 V
|
|
|
T003
|
Check: Circuit Interruption of Ground Circuit
|
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 3 & Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 2
|
4.8 ... 5.2 V
|
|
|
T004
|
Check: Short to Voltage/Ground/Interruption of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A84 Control Unit - Engine (Wiring Harness Connector XC11 )
- Ignition ON
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 4 & Ground
|
less than 0.3 V
|
|
|
T005
|
Check: Short to Ground of Signal Circuit
|
- Ignition OFF
- Measure resistance between:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 4 & Ground
|
greater than 500 kOhm
|
|
|
T006
|
Check: Interruption of Signal Circuit
|
- Measure resistance between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal 4 & A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 57 (XC11)
|
less than 5 Ohm
|
|
|