Adjustment data for Astra-H Z 20 LER (2.0 Turbo
ECOTEC) 147 kW
|
1
|
Vehicle manufacturer field no 2
|
|
Opel
|
2
|
Vehicle manufacturer code no 2
|
[HSN]
|
0035
|
3
|
Type and version field no 3
|
|
A - H
|
A - H / SW
|
A - H / C
|
4
|
Type and version code no 3
|
[TSN]
|
Fastback
|
Estate
|
GTC
|
Convertible
|
|
|
old
|
039
|
045
|
552
1)
|
563 2)
|
-
|
|
|
new
|
ADF
|
ADX
|
AEH
|
-
|
AAK
|
5.1
|
Engine code / model series / model year
|
|
LU2 / DOHC II / 2005 -
|
5.2
|
CLCC / EGR / knock control
|
[yes/no]
|
yes/no/yes
|
5.3
|
Manufacturer (mixture system)
|
|
Bosch
|
5.4
|
Fuel system
|
|
Fuel injection
|
5.5
|
Designation (engine management)
|
|
Motronic ME 7.6.2
|
5.6
|
Ignition system type
|
|
Direct ignition
|
5.7
|
Number of cylinders / arrangement of cylinders
|
|
4 / in-line
|
5.8
|
Capacity
|
[cm 3 ]
|
1998
|
5.9
|
Output
|
[kW/rpm]
|
147 / 5400
|
5.10
|
Max. torque
|
[Nm/rpm]
|
262 / 4200
|
5.11
|
Compression ratio
|
|
8.8 : 1
|
5.12
|
Bore x stroke
|
[mm] x [mm]
|
86.0 x 86.0
|
5.13
|
Trailer load, braked
|
[kg]
|
1500
|
1400
|
1500
|
1200
|
5.14
|
Trailer load, not braked
|
[kg]
|
L08 3)
|
L48 4)
|
|
|
|
|
|
|
|
680
|
690
|
710
|
680
|
750
|
5.15
|
Octane number requirement, recommended / alternative
|
[RON (MON)]
|
95
5) (85) / 98
5) 6) (88), 91
5)
7) (82.5)
|
5.16
|
Tax class / emissions class (D)
|
|
EURO 4
|
5.17
|
Code No.
|
[SN]
|
0462
|
6
|
Installation location diagnostic point
|
|
Centre console
|
7
|
Conditioning time [sec]
|
min.
|
30
|
8
|
Conditioning speed
|
[rpm]
|
|
9
|
Engine temperature min
|
[°C]
|
60
|
10.1
|
Idle speed, MT (min/max)
|
[rpm]
|
700 - 900
|
10.2
|
Idle speed, AT, position "P" (min/max)
|
[rpm]
|
-
|
11
|
Increased idle speed (min/max)
|
[rpm]
|
2800 - 3200
|
12
|
CO increased idle speed
|
[% vol]
|
0.2
|
13
|
Lambda increased idle speed (min/max)
|
|
0.97 - 1.03
|
14
|
Test speed (min/max), control sensor signal
|
[rpm]
|
700 - 900
|
15
|
Spring sensor(s) or wide band sensor(s)
|
|
S
|
16
|
Min. voltage increase
|
[mV]
|
300
|
17.1
|
Lambda value control sensor(s)
|
|
|
17.2
|
Control sensor(s) amperage
|
[mA]
|
|
17.3
|
Voltage control sensor(s)
|
[V]
|
|
Nos 7 + 8 are optional fields
|
|
|
|
Nos 17.1-17.3 apply for wide band sensors only
|
|
|
|