Test
|
Work Order Description
|
Nominal Value
|
T001
|
Tester Display Pump Relay Test
|
- Ignition ON
- Engine OFF
- Vehicle stationary
- Brake pedal actuated
- Parking brake applied
- Selector lever in position N
- Press corresponding key in the system main menu to call up Actuator-Test functions, select the desired test and confirm with ENTER . Follow the instructions in the diagnostic tester display.
|
|
Note:
The component is automatically deactivated after 5 s .
|
On
Hydraulic pump running
|
|
Off
Hydraulic pump not running
|
Concerned Terminals: 1 (XC83)
|
|
T002
|
Tester Display Clutch Test
|
- Ignition ON
- Engine OFF
- Vehicle stationary
- Brake pedal actuated
- Parking brake applied
- Selector lever in position N
- Press corresponding key in the system main menu to call up Actuator-Test functions, select the desired test and confirm with ENTER . Follow the instructions in the diagnostic tester display.
|
|
|
On
|
|
Off
|
Concerned Terminals: 7 (XC89)
|
|
T003
|
Tester Display Select Solenoid Valve Test
|
- Ignition ON
- Engine OFF
- Vehicle stationary
- Brake pedal actuated
- Parking brake applied
- Selector lever in position N
- Press corresponding key in the system main menu to call up Actuator-Test functions, select the desired test and confirm with ENTER . Follow the instructions in the diagnostic tester display.
|
|
|
On
|
|
Off
|
Concerned Terminals: 3 (XC89)
|
|
T004
|
Tester Display Shift Solenoid Valve Test
|
- Ignition ON
- Engine OFF
- Vehicle stationary
- Brake pedal actuated
- Parking brake applied
- Selector lever in position N
- Press corresponding key in the system main menu to call up Actuator-Test functions, select the desired test and confirm with ENTER . Follow the instructions in the diagnostic tester display.
|
|
- Press soft key REVERSE GEAR
|
Backward
|
|
Neutral
|
Concerned Terminals: 2 (XC89)
|
|