Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Interruption of Voltage Supply Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A163 Switch - Selector Lever
- Ignition ON
- Measure voltage between the following terminals:
A163 Switch - Selector Lever Wiring harness connector (wiring harness side) terminal 7 & Ground
|
greater than 11 V
|
|
|
T002
|
Check: Interruption of Voltage Supply Circuit
|
- Measure voltage between the following terminals:
A163 Switch - Selector Lever Wiring harness connector (wiring harness side) terminal 1 & A163 Switch - Selector Lever Wiring harness connector (wiring harness side) terminal 7
|
greater than 11 V
|
|
|
T003
|
Check: Short to Voltage of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A112 Control Unit - Transmission (Wiring Harness Connector XC82 )
- Ignition ON
- Measure voltage between the following terminals:
A163 Switch - Selector Lever Wiring harness connector (wiring harness side) terminal 12 & Ground
|
less than 0.3 V
|
|
|
T004
|
Check: Short to Ground of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A112 Control Unit - Transmission (Wiring Harness Connector XC82 )
- Measure resistance between the following terminals:
A163 Switch - Selector Lever Wiring harness connector (wiring harness side) terminal 12 & Ground
|
greater than 500 kOhm
|
|
|
T005
|
Check: Interruption of Signal Circuit
|
- Measure resistance between the following terminals:
A163 Switch - Selector Lever Wiring harness connector (wiring harness side) terminal 12 & A112 Control Unit - Transmission Wiring harness connector (wiring harness side) terminal 14 (XC82)
|
less than 5 Ohm
|
|
|
T006
|
Check: Short to Voltage of Signal Circuit
|
- Ignition ON
- Measure voltage between the following terminals:
A163 Switch - Selector Lever Wiring harness connector (wiring harness side) terminal 6 & Ground
|
less than 0.3 V
|
|
|
T007
|
Check: Short to Ground of Signal Circuit
|
- Ignition OFF
- Measure resistance between the following terminals:
A163 Switch - Selector Lever Wiring harness connector (wiring harness side) terminal 6 & Ground
|
greater than 500 kOhm
|
|
|
T008
|
Check: Interruption of Signal Circuit
|
- Measure resistance between the following terminals:
A163 Switch - Selector Lever Wiring harness connector (wiring harness side) terminal 6 & A112 Control Unit - Transmission Wiring harness connector (wiring harness side) terminal 18 (XC82)
|
less than 5 Ohm
|
|
|