Operational procedure
|
Paint stage
|
Products
|
Notes
|
|
I
|
II
|
III
|
|
|
Clean
|
x
|
x
|
x
|
Silicone remover
|
Spray on using pump atomiser and dry well using highly absorbent
cloth.
|
Sand
|
x
|
x
|
x
|
Wet or dry sandpaper
|
Sand out defect area, P180 grain. Roughen remaining area using
P280.
|
Putty application
|
x
|
–
|
x
|
Fine polyester putty
|
Apply three to four layers of fine putty to sanded-down bare
metal areas only.
|
Dry
|
x
|
–
|
x
|
Infrared lamp
|
Dry for 5 minutes.
|
Sand
|
x
|
–
|
x
|
Dry sandpaper
|
Only dry sand with polyester fine putty.
|
Clean
|
x
|
–
|
x
|
Silicone remover
|
Spray on using pump atomiser and dry well using highly absorbent
cloth.
|
Apply filler
|
x
|
–
|
x
|
2-C-acrylic-HS filler
|
Spray one to three layers of filler. Setting time 3 minutes.
Painting stage II includes minor repairs without putty application.
Multi-filler only to sanded-down areas for purposes of
insulation.
|
|
|
|
|
2-C-HS Multi-filler
|
|
Sand
|
x
|
–
|
x
|
Dry sandpaper
|
Not less than P320
|
|
|
|
|
Wet sandpaper
|
Not less than P800
|
Clean
|
x
|
x
|
x
|
Silicone remover
|
Spray on using pump atomiser and dry well using highly absorbent
cloth.
|
Spray top coat paint
|
x
|
x
|
x
|
VOC coat
100 parts of coat
50 parts of hardener
25 parts of thinner
|
Spray one thin layer. Setting time 1 to 3 minutes. Final
spraying with one more layer. Setting time 1 to 3 minutes before
oven drying.
|