1
|
Glow Plug (Qty: 4)
Caution: Refer to
Fastener Caution .
|
Caution: Use care when disconnecting the glow plug electrical
connector. Use of excessive force may damage the electrical
connector. |
Procedure
|
1. |
Be sure not to interchange the electrical
connectors. |
|
2. |
Assemble the electrical connectors in the same
order. |
|
3. |
Carefully assemble with the exact torque
value. |
|
4. |
Use EN-48390remover/installer for glow plugs
without pressure sensor. |
|
5. |
Use EN-6104remover/installer for glow plugs with
pressure sensor. |
Tighten
8 N·m (71 lb in)
Special Tools
• |
EN-48390 Remover/Installer Glow
Plugs 9 mm |
• |
EN-6104 Remover/Installer Glow
Plugs 12 mm |
For equivalent regional tools, refer to
Special Tools .
|