FCI Connectors (SIR)
Removal Procedure
Note: The orange connector
position assurance (CPA) must be released first to disconnect or to
connect the connector.
1. |
Lift the orange CPA vertically
(avoid lifting on an angle to the connector) approximately
4 mm to release the connector. Use a small flat-bladed tool
to help release the orange CPA. The orange CPA can also be released
manually without any tools. |
2. |
Grab the connector on both
sides and lift the connector vertically to disconnect the
connector. |
Installation Procedure
1. |
Lift the orange CPA vertically
approximately 4 mm before installing the connector. Use a
small flat-bladed tool to help release the orange CPA. The orange
CPA can also be released manually without any tools. |
2. |
Line up the connector key tabs
with the initiator key slots. Grab the connector on both sides and
push the connector down into the initiator connector sub assembly
until fully seated. |
3. |
After the connector is fully
seated, push down the orange CPA with your thumb. Push down until
the orange CPA is touching the yellow cover on the
connector. |
|