C-11, return pump relay circuit |
Test |
Work order description |
Nominal value |
T01 |
Check: Supply voltage of the pump relay |
|
|
• Ignition OFF • Disconnect wiring harness plug from: |
11.5...13.5 V |
|
K50 ABS control unit |
|
|
• Measure voltage between following terminals: |
|
|
K50 ABS control unit Wiring harness plug terminal 17 and 18 & Ground |
|
|
Yes: T02 |
No: E01 |
T02 |
Check: control unit ground connection |
|
|
• Measure voltage between following terminals: |
11.5...13.5 V |
|
K50 ABS control unit Wiring harness plug terminal 17 and 18 & K50 ABS control unit Wiring harness plug terminal 19 |
|
|
Yes: T03 |
No: E02 |
T03 |
Check: Pump motor ground connection |
|
|
• Measure voltage between following terminals: |
11.5...13.5 V |
|
K50 ABS control unit Wiring harness plug terminal 17 and 18 & K50 ABS control unit Wiring harness plug terminal 16 |
|
|
Yes: T04 |
No: E03 |
T04 |
Check: pump motor operation |
|
|
• Ignition OFF • Wiring harness plug connect from: |
OK |
|
K50 ABS control unit |
|
|
• Ignition ON • Select using TECH1: |
|
|
F5:ACTUATOR TEST NO. T01 RET.PUMP RELAY |
|
|
Yes: E05 |
No: E04 |