C-10, valve relay circuit |
Test |
Work order description |
Nominal value |
T01 |
Check: Supply voltage valve relay |
|
|
• Ignition OFF • Disconnect wiring harness plug from: |
11.5...13.5 V |
|
K50 ABS control unit |
|
|
• Measure voltage between following terminals: |
|
|
K50 ABS control unit Wiring harness plug terminal 17 and 18 & Ground |
|
|
Yes: T02 |
No: E01 |
T02 |
Check: Ground connection control unit |
|
|
• Measure voltage between following terminals: |
11.5...13.5 V |
|
K50 ABS control unit Wiring harness plug terminal 17 and 18 & K50 ABS control unit Wiring harness plug terminal 19 |
|
|
Yes: T03 |
No: E02 |
T03 |
Check: Ground connection valve relay |
|
|
• Measure voltage between following terminals: |
11.5...13.5 V |
|
K50 ABS control unit Wiring harness plug terminal 17 and 18 & K50 ABS control unit Wiring harness plug terminal 16 |
|
|
Yes: T04 |
No: E03 |
T04 |
Check: Tester |
|
|
• Ignition OFF • Wiring harness plug connect from: |
Active |
|
K50 ABS control unit |
|
|
• Ignition ON • Select using TECH 1 : |
|
|
F0:DATA LIST NO. T09 VALVE RELAY CMD |
|
|
Yes: E05 |
No: E04 |