Camshaft Hall Pulse Pick-up (Not Simtec)
Measurement: |
Plot of voltage at the signal output of the Hall sensor on the camshaft. |
Check Objective: |
Operational check |
Preparation
Switch off the engine and ignition.
Connections
INPUT A |
COM/TRIGGER |
Connect the red measurement lead to pin 2 (B) of the plug connector for the Hall sensor. Connect the ground lead to ground. |
|
Procedure
Start the engine and allow it to idle.
Reference Curve |
|
Fault Diagram |
|
Possible Causes |
Countermeasures |
Loose contact on the component plug or elsewhere in the wiring harness. |
Check all possible plug connections for continuity. |
Faulty Hall sensor. |
Replace Hall sensor. |
Notice:
In general a fault on the Hall sensor leads to total failure, i.e., the signal plot cannot be measured. In the event of this, replace the Hall sensor.