Install, Connect
Install solenoid cutoff valve control unit with new shear bolts - see operation "Solenoid Cutoff Valve Control Unit, Remove and Install (X 15 DT, X 17 D)".
Install oil cooler, fuel lines and intake manifold - see operation "Solenoid Cutoff Valve Control Unit, Remove and Install (X 15 DT, X 17 D)".
Notice:
The solenoid cutoff valve control does not require reprogramming after replacement of the solenoid cutoff valve.