vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Table 5, F5:ACTUATOR TEST Test Step 06 IGN. COIL CYL1+4 FREQUENCY 2/sec > < Table 5, F5:ACTUATOR TEST Test Step 04 IGNITION SPARK

Table 5, Multec-M (14 SE / C 14 SE / C 16 SE) F5:ACTUATOR TEST

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

05

IGN. COIL CYL1-4

 

FREQUENCY 2/sec

 

This test only applies to vehicles with Direct Ignition Systems DIS up to MY '93

 

Ignition OFF

Connect checking spark plug (1-4)

Ignition ON

Engine OFF

 

Press F5 key in the system main menu, using the arrow keys select the desired test and confirm with YES. Follow the instructions in the TECH 1 Display.

 

Note:

The checking spark plug is actuated at a frequency of 2 Hz (actuation period 10 ms). The test is completed after a maximum of 30 s.

 

Ignition spark visible at checking spark plug

 

42, 64

D 10/D 1

C 3/D 1

Trouble-shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

See trouble-shooting for Actuator Test 06 and 07

 

 

 

 

 

 


Related Literature Units
-Table 2, Trouble Code Table - TC 42 EST LINE VOLTAGE HIGH
-
-
-
-
-

Table 5, F5:ACTUATOR TEST Test Step 06 IGN. COIL CYL1+4 FREQUENCY 2/sec > < Table 5, F5:ACTUATOR TEST Test Step 04 IGNITION SPARK