vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Table 6, F6:ADJUSTMENTS CO ADJUSTMENTS - SEE CHECKING PROCEDURES > < Table 5, F5:ACTUATOR TEST Test Step 07 IGN. COIL CYL2+3 FREQUENCY 2/sec

Table 5, Multec-M (14 SE / C 14 SE / C 16 SE) F5:ACTUATOR TEST

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

08

A/C RELAY

Ignition ON

AC switch ON

 

Press F5 key in the system main menu, using the arrow keys select the desired test and confirm with YES. Follow the instructions in the TECH 1 Display.

 

Note:

After the test has been started, the AC cutoff relay switches.

Frequency: 1 Hz

The test is completed after a maximum of 30 s.

 

INACTIVE   12V

ACTIVE         0V

 

 

 

 

 

 

 

 

 

INACTIVE   12V

alternating

ACTIVE         0V

 

29,32

B 6/D 1

Trouble-shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

See test step 31

 

 

 

 

 

 

 


Related Literature Units
-F0:Data List - Test Step 31 A/C RELAY
-
-

Table 6, F6:ADJUSTMENTS CO ADJUSTMENTS - SEE CHECKING PROCEDURES > < Table 5, F5:ACTUATOR TEST Test Step 07 IGN. COIL CYL2+3 FREQUENCY 2/sec