vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Diagnostic Plug > < Illustration: Multec-M (C14SE)

 

Important Workshop Instructions  

 

-  Use only the program memory (PROM) allocated to the vehicle.  

-  Protect oxygen sensor from fuel and silicon. Do not clean with or allow contact with petrol.  

-  Do not apply underseal to catalytic converter or oxygen sensor or in their immediate area.  

-  Leaks (dead air) in the intake and exhaust system in front of the catalytic converter cause incorrect oxygen sensor readings.  

-  Leaks in the evaporation control system lead to irregular idle speeds.  

-  If injectors are leaky, the engine may run on after the ignition is switched off.  

-  If starting is poor, check the fuel system, fuel pump relay and ignition system.  

-  Before removing electric/electronic components, disconnect ground cable from the battery.  

-  When the battery is disconnected, all trouble codes stored in the memory and learned values for idle speed and mixture correction are deleted.  

-  Cylinder balance test.  

 

 

To prevent overheating of the catalytic converter, follow the time sequence outlined here for the cylinder balance test:  

 

-  Maximum switch-off duration of one cylinder 8 seconds.  

-  Minimum pause between each cylinder switch-off 8 seconds.  

-  When repeating the cylinder balance test, allow engine to run at idle speed for at least 60 seconds (recuperation) This time sequence is pre-programmed into the Opel/Vauxhall tester.  

 

 

 

Diagnostic Plug > < Illustration: Multec-M (C14SE)