Note: The fuel mixture at idle speed and partial load is corrected by the O2 BLM CELL CONTENT. If datalist parameter O2 INTEGRATOR deviates from the ideal (stoichiometric) air/fuel ratio for an extended period of time, the O2 BLM CELL CONTENT attempts to return it to the mean value of 128 . O2 BLM CELL CONTENT reacts especially to influences from altitude correction, air leaks, engine friction, fuel quality, etc. |
|