vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F0:Data List Test Step 33 O2 BLM CELL CONT > < F0:Data List Test Step 31 O2 BLM ENABLE

Multec- S X 14 XE /  X 16 XE (L)      F0:DATA LIST

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

32

O2 BLM CELL NO.

Engine running at idle speed, operating temperature (MT only)

18 or 19

13, 44, 45

-

 

 

Engine running at idle speed, operating temperature (AT only)

 

20 or 21

 

 

 

 

Engine running in partial load range, operating temperature

0 to 15

 

 

 

 

 

 

 

 

·   This test step indicates in which the block learn cell number the system is operating. If an incorrect block learn cell number is displayed, check the following fault causes:

 

Notes on Trouble-shooting:

Nominal Value:

Cause of fault:

(If nominal value is not attained)

 

·   Possible causes

 

 

·   Engine cold

·   Trouble code stored

·   Check following nominal values:

 

 

 

·   TECH 1 data list no. 05

     TPS SIGNAL

·   TECH 1 data list no. 06

     MAP SENSOR

·   TECH 1 data list no. 07

     COOLANT TEMP.

·   TECH 1 data list no. 08

     INTAKE AIR TEMP.

·   TECH 1 data list no. 27

     O2 SENSOR

 

OK

 

OK

 

OK

 

OK

 

OK

 

·   Remedy according to data list no. 05

     TPS SIGNAL

·   Remedy according to data list no. 06

     MAP SENSOR

·   Remedy according to data list no. 07

     COOLANT TEMP.

·   Remedy according to data list no. 08

     INTAKE AIR TEMP.

·   Remedy according to data list no. 27

     O2 SENSOR

 

·   Ignition OFF

·   Disconnect wiring harness plug from:

     K57 engine control unit

·   Check control unit calibration, see field remedy measures

 

Latest program memory (EPROM) according to field remedy measures or TIs

 

·   Replace program memory (EPROM) according to field remedy measures or TIs

 

 

If nominal values are attained and latest program memory is installed

·   K57 engine control unit defective

 

 

 

 

 

 

 


Related Literature Units
-F2:Trouble Codes - Trouble Code No. 13 O2 SENSOR OPEN CIRCUIT
-
-

F0:Data List Test Step 33 O2 BLM CELL CONT > < F0:Data List Test Step 31 O2 BLM ENABLE