Multec-
S X 14 XE / X 16 XE(L) F6:MISCELLANEOUS
TESTS F1:RESET
IAC BLM CELLS
Conditions for Checking
Nominal Value
Affected terminals: -
Possible trouble codes: -
Ignition OFF
Ignition ON
Engine OFF
Vehicle stationary
Press key F6 in the system main menu, select the reset mode
with key F1. Using the arrow keys, select the desired control unit reset and
confirm with YES. Follow the instructions in the TECH 1 display.
Trigger reset by pressing key "arrow up"
F0:DATA LIST no. 43
IMPORTANT:
During the control unit reset, RST
is displayed in the bottom right corner of the TECH 1 display.
RESET
IAC
BLM CELLS
Note:
The learned value is reset to allow the air required by an
engine at idle speed to be evaluated. Depending on the reaction of the
control unit, the mechanic / Service technician can evaluate whether, for
example, dead air or an incorrect fuel pressure is the cause for the
deviation of the IDLE AIR CONTROL
parameter.