Nominal idle speed has been programmed:
Note:
The nominal engine speed is a programmable value.
If F0:DATA LIST no.: 37 is ACTIVE, the nominal engine speed has
been reprogrammed.
If F0:DATA LIST no.: 37 is INACTIVE, the nominal engine speed
has not been altered or the control unit has been reset. In this case, ignore
the TECH 1 display. A randomly selected value will be displayed.
|
The nominal engine speed set in F6:Miscellaneous Tests,
F0:Adjustments must appear in the display
|
|
|
· Select
TECH 1 menu:
F6:MISC. TESTS,
F0:ADJUSTMENTS
· Program new
idle speed 950 rpm
· TECH 1
data list no. 37
IDLE ADJUST
· TECH 1
data list no. 36
DES. IDLE
ADJUST
|
ACTIVE
950 rpm
|
· Check control
unit calibration, see field remedy measures
|
· Select
TECH 1 menu:
F6:MISC. TESTS,
F1:ECU RESET
· TECH 1
data list no. 37
IDLE ADJUST
· TECH 1
data list no. 36
DES. IDLE
ADJUST
X 14 XE / X 16 XE:
X 16 XEL:
|
INACTIVE
850 rpm
900 rpm
|
· Check control
unit calibration, see field remedy measures
|