· Engine running since at
least 40 s
· Coolant temperature
higher than 75 °C/ 167 °F
· Throttle valve aperture
greater than 0 %
· Following trouble codes
not stored: 21, 22, 33, 34
· The fault is recognised
by the control unit if the oxygen sensor voltage is in the range 343 to
540 mV for longer than 20 s
(circuit interruption, oxygen sensor defect).
Replacement
value:
· 450 mV
Effect:
· Oxygen sensor regulation
is switched off, i.e. open oxygen sensor loop
Note:
The oxygen
sensor must not be wrapped in aluminium foil. Remove foil.
Then delete
trouble code. If trouble code 13 is set again, start trouble-shooting
according to F0:DATA LIST no. 27.
|