vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Illustration: Air Ducts (X 14 XE, C 14 SEL, X 16 XE, C 16 SEL) > < Tank Vent Valve, Remove and Install reinstallation

 

Reference Gap Between Inductive Pulse Pick-up and Increment Disc, Measure  

Object Number: 616197  Size: DEFAULT  Measure   

Measure the gap (arrows) between inductive pulse pick-up and increment disc with feeler gauge.  

Nominal value - 1.0 ± 0.7 mm.  

If the nominal value is not reached, the pulse pick-up bracket must be replaced - 10 Nm / 7 lbf. ft.  

Object Number: 2385552  Size: DEFAULT

 

Illustration: Air Ducts (X 14 XE, C 14 SEL, X 16 XE, C 16 SEL) > < Tank Vent Valve, Remove and Install reinstallation