Reference Gap Between Inductive Pulse Pick-up and Increment Disc, Measure
Measure
Measure the gap (arrows) between inductive pulse pick-up and increment disc with feeler gauge.
Nominal value - 1.0 ± 0.7 mm.
If the nominal value is not reached, the pulse pick-up bracket must be replaced - 10 Nm / 7 lbf. ft.