• No Diagnostic-Mode (diagnostic tester not connected) • Short to voltage in circuit to control unit terminal C14 • Above conditions must be fulfilled for 6 consecutive ignitions Effect: • The injectors of the cylinder pair 1, 4 are switched off • The oxygen sensor control is locked. Concerned Terminals: C14 |