• Self-test 1 of exhaust gas recirculation system: (position measurement valve piston for closed exhaust gas recirculation valve) Deviation of the actual value to the nominal value of the exhaust gas recirculation position sensor is greater than 2 % for longer than 4 s or • Self-test 2 of exhaust gas recirculation system: (position measurement valve piston for open exhaust gas recirculation valve) Deviation of the actual value to the nominal value of the exhaust gas recirculation position sensor is greater than 12 % for longer than 4 s Effect: • Exhaust gas recirculation valve is switched off Concerned Terminals: D2, D8, B2 |