Only X 14 XE, X 16 XE, X 16 XEL : • Ignition ON • Engine OFF • Press corresponding key in the system main menu to call up Actuator Test functions, select the desired test and confirm with YES. Follow the instructions in the diagnostic tester display. Note: The following faults can be recognised with this actuator test: Short to ground or interruption in circuit to control unit terminal C2, C3, C4, C6 Short to voltage in circuit to control unit terminal C2, C3, C4, C6 |