C-17, Ignition Coil B Primary/Secondary Circuit |
Test |
Work Order Description |
Nominal Value |
T01 |
Check: Short to Ground/Interruption of Voltage Supply Circuit |
|
|
• Ignition OFF • Disconnect wiring harness connector from: L2 Ignition Coil • Ignition ON • Measure voltage between the following terminals: L2 Ignition Coil Wiring Harness Connector Terminal 1 & Ground |
greater than 11.5 V |
|
Yes: T02 |
No: E05 |
T02 |
Check: Circuit Interruption of Ground Circuit |
|
|
• Measure voltage between the following terminals: L2 Ignition Coil Wiring Harness Connector Terminal 1 & L2 Ignition Coil Wiring Harness Connector Terminal 2 |
greater than 11.5 V |
|
Yes: T03 |
No: E04 |
T03 |
Check: Component |
|
|
• Connect fused jumper wire to: L2 Ignition Coil Wiring Harness Connector Terminal 1 & L2 Ignition Coil Terminal 1 and L2 Ignition Coil Wiring Harness Connector Terminal 2 & L2 Ignition Coil Terminal 2 • Connect test spark plugs to ignition leads for cylinders 2 and 3. • Use a fused jumper wire and cyclically contact the following terminal: L2 Ignition Coil Terminal 4 & Battery Voltage (Positive Terminal) |
Ignition sparks visible at both test spark plugs. |
|
Yes: T04 |
No: E03 |
T04 |
Check: Short to Voltage/Ground/Interruption of Signal Circuit |
|
|
• Ignition OFF • Disconnect wiring harness connector from: K57 Control Unit - Multec • Connect wiring harness connector to: L2 Ignition Coil • Ignition ON • Connect test spark plugs to ignition leads for cylinders 2 and 3. • Use a fused jumper wire and cyclically contact the following terminal: K57 Control Unit - Multec Wiring Harness Connector Terminal D14 & Battery Voltage (Positive Terminal) |
Ignition sparks visible at both test spark plugs. |
|
Yes: E01 |
No: E02 |