vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Quick Check F5:ACTUATOR TEST No. 03 SELECT ACTUATOR IGN. COIL CYL1+4 > < Quick Check F5:ACTUATOR TEST No. 01 SELECT ACTUATOR IDLE AIR CONTROL

Multec (X 12 SZ / X 16 SZ) Quick Check F5: ACTUATOR TEST

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

02

SELECT ACTUATOR QUAD DRIVER TEST

 

Ignition ON

Engine OFF

 

Press F5 key in the system main menu, select the desired test with the arrow keys and confirm with YES. Follow the instructions in the TECH 1 display.

If the test is faulty, see causes below

 

OKAY?

Engine telltale must flash

Exhaust gas recirculation valve must switch

Controlled canister purge valve must switch

 

93

 

 

TEST FAILED!

More than one circuit defective, control unit possibly faulty

 

 

 

 

Trouble - shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

 

Check components see F0: DATA LIST test steps 16, 22, 32 and 36

 

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

 

QUAD DRIVER TEST LINEAR EGR STATUS VOLTAGE LOW

 

Short circuit to ground

(interruption in circuit)

 

93

A 9

 

 

 

 

 

 

Trouble - shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

 

·   Ignition OFF

·   Disconnect wiring harness plug, exhaust gas recirculation module V 15

·   Using multimeter, measure resistance:

from:   wiring harness plug, exhaust gas recirculation module V 15 Ter. B

to:        ground

greater than 100 kW

·   Short circuit in wiring harness

from:   wiring harness plug, exhaust gas recirculation module V 15 Ter. B

to:        ground

 

·   Disconnect control unit wiring harness plug K 57

·   Using multimeter, measure resistance:

from:   wiring harness plug, exhaust gas

recirculation module V 15 Ter. B

to:        control unit wiring harness plug K 57 Ter. A 9

 

less than 2 W

·   Lead interruption

from:   wiring harness plug, exhaust gas recirculation module V 15 Ter. B

to:        control unit wiring harness plug K 57 Ter. A 9

·   If nominal values are attained carry out F0: DATA LIST test step no. 16

 

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

 

QUAD DRIVER TEST LINEAR EGR STATUS VOLTAGE HIGH

 

Short circuit to ground

 

 

93

A 9

 

 

 

 

 

 

Trouble - shooting:

Nominalalue:

Cause of Fault:

(If nominal value is not attained)

 

·   Ignition ON

·   Measure voltage:

from:   wiring harness plug, exhaust gas recirculation module V 15 Ter. B

to:        ground

 

less than 0.1 V

·          Short circuit in wiring harness from:    wiring harness plug, exhaust gas recirculation module V 15 Ter. B

to:        battery +

 

·   If nominal values are attained carry out F0: DATA LIST test step no. 16

 

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

 

QUAD DRIVER TEST TANK VENT. VALVE VOLTAGE LOW

 

Short circuit to ground

(Interruption in circuit)

 

93

A 10

 

 

 

 

 

 

Trouble - shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

 

·   Ignition OFF

·   Disconnect wiring harness plug, controlled canister purge valve Y 32

·   Using multimeter, measure resistance:

from:   wiring harness plug, controlled canister purge valve Y 32 Ter. A

to:        ground

 

greater than 100 kW

·   Short circuit in wiring harness

from:   wiring harness plug, exhaust gas recirculation module V 15 Ter. B

to:        ground

·   Disconnect control unit wiring harness plug K 57

·   Using multimeter, measure resistance:

from:   wiring harness plug, controlled canister purge valve Y 32 Ter. A

to:        control unit wiring harness plug K 57 Ter. A 10

 

less than 2 W

·   Lead interruption

from:   wiring harness plug, controlled canister purge valve Y 32 Ter. A

to:        control unit wiring harness plug K 57 Ter. A 10

·   If nominal values are attained carry out F0: DATA LIST test step no. 22

 

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

 

QUAD DRIVER TEST FUEL TANK VENT. VALVE VOLTAGE HIGH

 

Short circuit to battery voltage.

 

 

93

A 10

 

 

 

 

 

 

Trouble - shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

 

·   Ignition ON

·   Measure voltage:

from:   wiring harness plug, controlled canister purge valve Y 32 Ter. A

to:        ground

 

less than 0.1 V

·   Short circuit in wiring harness

from:   controlled canister purge valve Y 32 Ter. A

to:        battery +

 

·   If nominal values are attained carry out F0: DATA LIST test step no. 22

 

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

 

QUAD DRIVER TEST CHECK LIGHT VOLTAGE LOW

Short circuit to ground

Fuse defective F7

(Interruption in circuit)

 

93

C 1

 

 

 

 

 

 

Trouble - shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

 

·   Ignition OFF

·   Disconnect instrument panel wiring harness plug X 21

·   Using multimeter, measure resistance:

from:   instrument panel wiring harness plug X 21 Ter. 12

to:        ground

 

greater than 100 kW

·   Short circuit in wiring harness

from:   instrument panel wiring harness plug X 21 Ter. 12

to:        ground

·   Disconnect control unit wiring harness plug K 57

·   Using multimeter, measure resistance:

from:   instrument panel wiring harness plug X 21 Ter. 12

to:        control unit wiring harness plug K 57 Ter. C 1

 

less than 2 W

·   Lead interruption

from:   instrument panel wiring harness plug X 21 Ter. 12

to:        control unit wiring harness plug K 57 Ter. C 1

·   If nominal values are attained carry out F0: DATA LIST test step no. 36

 

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

 

QUAD DRIVER TEST CHECK LIGHT VOLTAGE HIGH

 

Short circuit to battery voltage

Telltale system defective

 

93

C 1

 

 

 

 

 

 

Trouble - shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

 

·   Ignition ON

·   Measure voltage:

from:   instrument panel wiring harness plug X 21 Ter. 12

to:        ground

less than 0.1 V

·   Short circuit in wiring harness

from:   instrument panel wiring harness plug X 21 Ter. 12

to:        battery +

 

 

 

·   If nominal values are attained carry out F0: DATA LIST test step no. 36

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

 

QUAD DRIVER TEST TN SIGNAL VOLTAGE HIGH

 

Short circuit to battery voltage

(circuit interruption)

 

See F0: DATA LIST No.: 32

 

75

B 5, D 7, C 5

 

 

 

 

 

 

Trouble - shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

 

Automatic transmission only

 

·   Disconnect control unit wiring harness plug K 57

·   Ignition OFF

·   Using multimeter, measure resistance:

from:   control unit wiring harness plug K 57 Ter. B 5

to:        ground

 

greater than 100 kW

·   Short circuit in wiring harness

from:   control unit wiring harness plug K 57 Ter. B 5

to:        ground

·   Using multimeter, measure resistance:

from:   control unit wiring harness plug K 57 Ter. D 7

to:        ground

 

greater than 100 kW

·   Short circuit in wiring harness

from:   control unit wiring harness plug K 57 Ter. D 7

to:        ground

·   Using multimeter, measure resistance:

from:   control unit wiring harness plug K 57 Ter. C 2

to:        ground

 

greater than 100 kW

·   Short circuit in wiring harness

from:   control unit wiring harness plug K 57 Ter. C 2

to:        ground

·   If nominal values are attained carry out F0: DATA LIST test step no. 33

 

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

 

QUAD DRIVER TEST TN SIGNAL VOLTAGE HIGH

 

Short circuit to battery voltage

 

See F0: DATA LIST No.: 32

 

75, 76

B 5, D 7, C 2

 

 

 

 

 

 

Trouble - shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

 

Only Astra - F

 

·   Ignition ON

·   Measure voltage:

from:   control unit wiring harness plug K 57 Ter. B 5

to:        ground

 

less than 0.1 V

·   Short circuit in wiring harness

from:   control unit wiring harness plug K 57 Ter. B 5

to:        battery +

·   Measure voltage:

from:   control unit wiring harness plug K 57 Ter. D 7

to:        ground

 

less than 0.1 V

·   Short circuit in wiring harness

from:   control unit wiring harness plug K 57 Ter. D 7

to:        battery +

·   Measure voltage:

from:   control unit wiring harness plug K 57 Ter. C 2

to:        ground

less than 0.1 V

·   Short circuit in wiring harness

from:   control unit wiring harness plug K 57 Ter. C 2

to:        battery +

 

·   If nominal values are attained carry out F0: DATA LIST test step no. 33

 

 

 

 

 


Related Literature Units
-F2:Trouble Code Table - Trouble Code 93 QUAD DRIVER MODULE (QDM)

Quick Check F5:ACTUATOR TEST No. 03 SELECT ACTUATOR IGN. COIL CYL1+4 > < Quick Check F5:ACTUATOR TEST No. 01 SELECT ACTUATOR IDLE AIR CONTROL