vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Quick Check F5:Actuator Test AIR CONTR. SOL > < F2:Trouble Codes - Trouble Code No. 56 AIR CONTROL SOL. VOLTAGE LOW

Multec- S X 14 XE / X 16 XE(L)        F2:TROUBLE CODES

 

Trouble Code

Information Sensor Cause of Fault

Remedy in F0:DATA LIST No.

Trouble Code Storage when...

57

AIR CONTROL SOL. VOLTAGE HIGH

23

·   Final stage diagnosis in control unit:

     Incorrect voltage condition at output Ter. A11 of control unit (short circuit to voltage)

·   Above condition must be fulfilled for at least 2 s

 

 

 

 

 

 

 

 


Related Literature Units
-F0:Data List Test Step 23 AIR CONTROL SOL.

Quick Check F5:Actuator Test AIR CONTR. SOL > < F2:Trouble Codes - Trouble Code No. 56 AIR CONTROL SOL. VOLTAGE LOW