F5:ACTUATOR TEST HORN > < F0:DATA LIST - Test Step 21 HORN

Anti-theft Warning System ATWS          Quick Check F5:ACTUATOR TEST

 

CHECK LIGHT

 

Conditions for Checking

Nominal Value

Affected terminals:                   2

Possible trouble codes:             -

 

Ignition ON

Press key F5 in the system main menu, select the desired test using the arrow keys and confirm with YES. Follow the instructions in the TECH 1 display.

Start actuator test

 

TECH 1 display:

CHECK LIGHT

 

 

alternating

OFF      0V

and

ON      12V

LED in hazard warning lamps switch flashes

Note:

The LED is actuated at a frequency of 0.5 Hz (switch-on period 1 s).

The check is completed after a maximum of 30 s.

 

 

 

 

 

 