Central Door Locking System with Anti-Theft Device - Corsa-B
Test
Step
Tester Multimeter
Notes
Nominal Value
MKM-587-A
of
between
1
Voltmeter, range 20 V, DC
Voltage supply for control unit K 37 and servo motors
K 37/
Ter. 9
Ground
· Remove control unit K 37
· Measurement at wiring harness plug K 37
greater than
11,5 V
Possible faults:
(if nominal value is not attained)
1. Fuse F 13 defective.
2. Interruption in instrument panel wiring harness between fuse F 13 and body wiring harness plug X 7/Ter. 37.
3. Interruption in body wiring harness between body wiring harness plug X 7/Ter. 37 and wiring harness plug
K 37/Ter. 9.