Central Door Locking System with Anti-Theft Device - Corsa-B
Test
Step
Tester Multimeter
Notes
Nominal Value
MKM-587-A
of
between
5
Ohmmeter, range:
Input and output leads at control unit K 37
K 37/
Ter. 2
Ground
· Perform measurements before inserting new control unit
approx. 0 W 1)
1) 200 W
2) 20 MW
Ter. 6
· Lock CDLS at all doors
greater than
20 MW 2)
Ter. 11
Ter. 12
· All measurements between wiring harness plug K 37 and body ground
· Unlock CDLS at all doors
Possible faults:
(if nominal value is not attained)
Measured resistance lower than nominal value:
short circuit in body wiring harness.
Measured resistance higher than nominal value:
interruption in body wiring harness.