vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Charge Pressure Regulation Solenoid Valve > < J741100 Charge Pressure Sensor, Replace (Y 17 DTL)

J740500 Coolant Temperature Sensor, Replace (Y 17 DTL, without AC, LHD)

1. Open bonnet

Object Number: 2411059  Size: DEFAULT

2. Drain coolant

  • Place collecting basin underneath.
  • Remove drain bolt

3. Remove coolant temperature sensor (1)

  • Detach wiring harness plug (2).
  • Unscrew sensor
Object Number: 2411114  Size: DEFAULT

4. Install coolant temperature sensor

  • Tighten sensor (22.5 Nm / 16.6 lbf. ft.) 1) .
  • Connect wiring harness plug.

5. Close coolant drain bolt

6. Top up coolant

  • Note! Top up and bleed cooling system – see operation "Top up and bleed cooling system"
  • Observe specified coolant quantity

7. Close bonnet


1 ) Recut threads before re-use and insert bolts with screw locking compound (red). Installation time including the torque test is max. 10 min.