Fan Regulator ECC, Remove and Install
Remove
Important: When
replacing the control unit, carry out reset with Tech2 before
removing the control unit.
|
1. |
Remove footwell inner panelling
• |
Unclip footwell panelling (1)
|
|
2. |
Remove footwell air duct (3)
• |
Unclip body-bound rivet
|
|
|
|
3. |
Remove ECC fan regulator (3)
• |
Release and separate 3x wiring harness plug (1)
|
|
|
Install
4. |
Install ECC fan regulator
• |
Connect and latch 3 wiring harness plugs
|
|
5. |
Install air duct, footwell
• |
Clip in body-bound rivet
|
|
6. |
Attach footwell inner panelling
• |
Clip in footwell panelling
|
|
Important: When replacing the
control unit, carry out reset with Tech2 before removing the
control unit.
|
7. |
Program volatile memories
|
|