vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Pull-Down Cell > < Fast Idle, Check and Adjust

 

 

Idle Speed and CO Content, Adjust

 

Preconditions:

Correct engine functioning - valves, valve timing.

Oil temperature >80 °C/176 °F.

Correct functioning of injection system.

Intake system leak-free.

Clean air cleaner installed.

Correct intake air pre-heating.

Correct accelerator actuation.

Electrical consumers switched off.

Hose for crankcase ventilation removed and closed off to air cleaner.

 

 

Object Number: 2375560  Size: DEFAULT

 

 

Preconditions:

Tachometer and CO-tester connected.

Adjustment screw (3) must not touch stepped plate (4).

 

Adjust idle speed at throttle valve stop screw (1).

If necessary, correct CO content at mixture adjusting screw (C 0212/2).

Test values - see Technical Data.

 

If this adjustment is not possible, see "Trouble-shooting Chart".

After adjustment, attach lead seal.

 

 

Object Number: 2380702  Size: DEFAULT

 

 

Pull-Down Cell > < Fast Idle, Check and Adjust