vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F0:Data List - Test Step 04 INTAKE AIR TEMP. > < F0:Data List - Test Step 01 BATTERY VOLTAGE

Multec-M (14 SE / C 14 SE / C 16 SE) F0:DATA LIST

 

 

 

 

 

less than -35 °C/-95 °F

greater than 4,9 V

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

03

COOLANT TEMP.

Engine running at idle speed,

operating temperature

(Voltage {V} changes at approx. 50 °C/122 °F)

 

85 to 110 °C/

185 to 230 °F

2.21 to 1.43 V

14,15

B 12/A 11

Trouble-shooting:

Nominal Value:

Cause of Fault:

(If nominal value is not attained)

·   Ignition OFF

·   Disconnect coolant temperature sensor plug P 30

·   Disconnect intake air temperature sensor plug P 29

·   Disconnect intake manifold pressure sensor plug P 23

·   Ignition ON

 

 

 

 

 

 

 

less than -35 °C/-95 °F

greater than 4,9 V

·   Short circuit in wiring harness

from:      coolant temperature sensor P 30 (BL)

to:          ground

or

from:      coolant temperature sensor P 30 (BR)

to:          coolant temperature sensor P 30 (BL)

 

·   Ignition OFF

·   Connect intake air temperature sensor plug P 29

·   Ignition ON

 

 

 

 

less than -35 °C/-95 °F

greater than 4,9 V

 

·   Intake air temperature sensor P 29 defective

 

·   Ignition OFF

·   Connect intake manifold pressure sensor plug P 23

·   Ignition ON

 

 

·   Intake manifold pressure sensor P 23 defective

 

 

·   Ignition OFF

·   Bridge coolant temperature sensor plug P 30:

from:      wiring harness plug (BR: brown)

to:          wiring harness plug (BL: blue)

·   Ignition ON

 

 

 

 

 

 

greater than 145 °C/

293 °F

less than 0,1 V

 

 

·   Lead interruption

from:      coolant temperature sensor P 30 (BL)

to:          control unit K 57/K 91 Ter. B 12

or

from:      coolant temperature sensor P 30 (BR)

to:          control unit K 57/K 91 Ter. A 11

·   Control unit defective

 

 

If nominal values are attained

 

·   Coolant temperature sensor P 30 defective

 

 

 

 

 

 


Related Literature Units
-Table 2, Trouble Code Table - TC 14 COOLANT TEMP. VOLTAGE LOW
-

F0:Data List - Test Step 04 INTAKE AIR TEMP. > < F0:Data List - Test Step 01 BATTERY VOLTAGE