· The control unit has determined a voltage
condition at the output to the injector which does not correspond to the
nominal value (3 consecutive 0 V to 12 V transitions were not registered)
The
fault (lead interruption/short circuit to ground) is recognized when the
ignition is switched on and after the switch-on test.
Short
circuit to ground:
Injector
is always actuated
Engine
does not start
The
catalytic converter may become damaged
Interruption:
The
injector is no longer actuated
|