Breaker Point, Replace on 10 S, 12 NC
Remove
Remove distributor cap, distributor rotor and condensation
barrier.
Unscrew breaker point and remove cable plug.
|
|
Install
Bolt on breaker point and connect cable plug.
Grease cam on distributor shaft and thrust part of breaker
arm with Special Grease 19 41 574 (90 001 812).
Adjust dwell angle (see corresponding operation).
Install condensation barrier, distributor rotor and