C 14 SE and C 16 SE, attach bracket for
inductive pulse pick -up to oil pump.
Then check the reference dimension between the inductive
pulse pick - up and the increment disc - see corresponding operation.
Install oil pressure switch/sensor and oil intake pipe with
new gasket.
Tightening torques:
oil pump to cylinder block - 6 Nm/4 lbf. ft.
oil pressure switch/sensor
to oil pump - 30 Nm/22
lbf. ft.
oil intake pipe to oil pump - 8 Nm/6 lbf. ft.
*
* Insert bolts with Locking Compound
15 10 177 (90 167 347).
|