Safety Valve of Oil Pump, Replace

 

With C 16 SEI engine remove bracket for inductive pulse sensor and tie to one side.

 

 

Object Number: 2380699  Size: DEFAULT

 

 

Unscrew closure plug and remove spring and piston from behind plug.

 

 

Object Number: 2381093  Size: DEFAULT

 

 

With symptoms such as illuminated or flickering telltale, due to insufficient oil pressure, check piston of safety valve for clearance and adhering dirt particles.

 

Illus. D 1640 shows safety valve arrangement.

 

 

Object Number: 2381090  Size: DEFAULT

 

 

Install safety valve, use new copper seal ring.

 

With C 16 SEI engine install bracket for inductive pulse sensor.

 

Important:       Check gap measurement between TDC sensor and segment disc.

                          See operation "Inductive Pulse Sensor, Adjust".

 

Tightening torques:

Closure plug to oil pump - 30 Nm/22 lbf. ft.

Inductive pulse sensor bracket to cylinder block - 45 Nm/33 lbf. ft.

 


Related Literature Units
-