· Monitoring
is activated after switch - on test. Battery voltage is measured
continuously and assessed periodically
· Battery
voltage is less than 8.8 V with ABS active (braking and ABS is required)
· Battery
voltage is not in the range of 9.4 V to 17.3 V with ABS inactive
(braking and ABS is not required).
Effects:
· Correct
functioning of the ABS valves and the return pump is no longer ensured
· ABS
is not switched off
· ABS
telltale is switched on
Note:
While voltage is too high or too
low, the ABS valves are switched passively and a possible start of the return
pump is prevented.
|