Remedy:
When
replacing coolant lines, maintain the following procedure when connecting.
· Connect quick couplings (1) up to stop in heater pipe connecting
piece (2).
· Press retaining ring (3) in the direction of the bulkhead.
Important:
With
correct connection, green locking ring (5) must spring out of quick coupling.
· Remove green locking ring from heater pipe.
Note:
The
green locking ring is only present with newly ordered coolant lines with
quick coupling.
When
installing the original coolant line, the recess (4) must enclose collar (6).
Time Allowance:
The time allowances remain unchanged.
|