· Charge pressure lower than 480 hPa
(0.48 bar) (voltage lower than 710 mV)
(interruption
or short circuit to ground)
· Condition must be fulfilled for at
least 3.5 s
Replacement values:
· Charge pressure: 1000 hPa
(1.0 bar)
· Atmospheric pressure: 850 hPa
(0.85 bar)
Effects:
· Maximum output is reduced.
· The injection amount is reduced to 21
mg/ stroke.
|