05
|
SELECT ACTUATOR
IDLE AIR CONTR
|
Ignition ON
Engine OFF
Press key F5 in the system
main menu, select the desired test using the arrow keys and confirm with YES.
Follow the instructions in the
TECH 1 display.
Note:
The idle air stepper control
switches at a frequency of 0.5 Hz.
The check is completed after a
maximum of 30 s.
Actuation duration 1 s.
|
Noise check:
Clicking noise from idle speed
stepper motor
|
56,
57
|
4,
24
|
· Disconnect
plug from idle speed adjuster M 33
· Ignition
ON
· Using
multimeter, measure voltage at idle speed adjuster plug M 33 / RTBL
(red / blue) to ground
|
11.5 to 13.5 V
|
· Lead
interruptions from control unit K 61 / Ter. 37 or from
injectors relay K 43 / Ter. 8 to idle speed adjuster
M 33 / RTBL (red / blue)
|
· Ignition
OFF
· Disconnect
control unit K 61 from wiring harness
· Using
multimeter, check from idle speed adjuster plug M 33 / BRBL
(brown / blue) to control unit K 61 / Ter. 4 for passage
and short circuit to ground
|
Passage
|
· Short
circuit or lead interruption from idle speed adjuster M 33 / BRBL
(brown / blue) to control unit K 61 / Ter. 4
|