Motronic M 2.8.1 Quick Check F0: DATA LIST
No.
|
TECH 1 Display
|
Conditions for
Checking
|
Nominal Value
|
Trouble Codes
|
Terminal
|
27
|
INT.
MANIFOLD V.1
|
Engine running at idle speed,
operating temperature
|
INACTIVE 12V
|
59,
63, 123,
|
6, 24
|
|
|
Depress accelerator pedal
briefly to full load stop
|
ACTIVE 0V
|
|
|
|
|
Note:
For this test, the engine must
first run for a few seconds at idle speed before the accelerator pedal is
quickly depresed to the full load stop.
|
|
|
|
|
|
|
|
|
|
|