Inspect
Opening pressure:
Before starting, actuate tester several times with the gauge
closed to rinse the injection nozzle. To check, open gauge, press
down hand lever slowly, until injection nozzle sprays. Read off
pressure from gauge. If the value read off does not correspond to
the prescribed opening pressure of 15000 to 15800 kPa (150 to 158
bar), the injection nozzle must be replaced.
|
|