vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

F5: ACTUATOR TEST - No. 07 SEC. AIR P.REL > < F5: ACTUATOR TEST - No. 03 FUEL PUMP REL.

SIMTEC 56.1              Quick Check F5: ACTUATOR TEST

 

A/C CUTOFF REL

 

Conditions for Checking

Nominal Value

Affected Terminals: 53, 41

 

Possible Trouble Codes: 87, 88

 

 

Vehicles with AC:

 

This check can be performed in two operating conditions: "ignition ON, engine off" and "engine running at idle speed".

 

The first part of the check should be carried out if the engine cannot be started:

otherwise the second part allows accurate diagnosis.

 

 

Check 1:

 

 

Ignition ON

 

 

Engine OFF

 

 

AC switch ON

 

 

Press F5 in the system main menu, select desired test with arrow keys and confirm with YES. Follow instructions in the TECH 1 display.

The AC cutoff relay switches alternately:

INACTIVE  12V

ACTIVE     0V

Note:

 

The AC cutoff relay is actuated at a frequency of 0.5 Hz (actuation duration 1 s).

 

The check is completed after a maximum of 30 s.

Noise check:

 

clicking noise from relay

Check 2:

 

 

Engine running at idle speed

 

 

AC switch ON

 

 

Press F5 in the system main menu, select desired test with arrow keys and confirm with YES. Follow instructions in the TECH 1 display.

The AC cutoff relay switches alternately:

INACTIVE  12V

ACTIVE     0V

Note:

 

The AC cutoff relay is actuated at a frequency of 0.5 Hz (actuation duration 1 s).

 

The check is completed after a maximum of 30 s.

AC compressor switches ON and OFF

(clicking noise from compressor and from relay)

 

 


Related Literature Units
-F2: TROUBLE CODES - Trouble Code 87 A/C CUTOFF RELAY VOLTAGE LOW
-

F5: ACTUATOR TEST - No. 07 SEC. AIR P.REL > < F5: ACTUATOR TEST - No. 03 FUEL PUMP REL.