· Engine
not in operating condition:
engine stationary, start,
deceleration fuel cutoff and engine speed limitation
· Short
circuit to ground
· Conditions
must be fulfilled for at least 3.5 s
Effects:
· Oxygen
sensor regulation and controlled canister purge valve regulation are blocked
· Controlled
canister purge valve is closed
· All
adaptation except throttle valve regulation and idle air control is blocked.
|