No.
|
TECH 1 Display
|
Conditions for Checking
|
Nominal Value
|
Trouble Codes
|
Terminal
|
02 |
IGNITION STATUS
|
Ignition
OFF
Ignition
ON
Note:
The
data connection between TECH 1 and the control unit may be interrupted
when the ignition is switched on or off. The connection should however be
re-established after a maximum of 45 s.
|
OFF 0V
ON 12V
|
35
|
30
|
Notes
on Trouble-shooting: |
Nominal
Value:
|
Cause
of Fault:
(If
nominal value is not attained)
|
· Release and disconnect wiring harness plug
K94 from ATWS control unit |
|
|
· Switch on ignition |
|
|
· Using multimeter, measure battery voltage |
greater
than 9 volts
|
· Body wiring harness, interruption
from: ignition lock S1/Ter. 15
to: wiring harness plug K94/Ter. 30
|
If nominal values are attained: |
|
· Control unit K94 defective
|
|
|
|
|
|
|
|